66 research outputs found
Improved Measurement of the Positive Muon Anomalous Magnetic Moment
A new measurement of the positive muon's anomalous magnetic moment has been
made at the Brookhaven Alternating Gradient Synchrotron using the direct
injection of polarized muons into the superferric storage ring. The angular
frequency difference omega_{a} between the angular spin precession frequency
omega_{s} and the angular orbital frequency omega_{c} is measured as well as
the free proton NMR frequency omega_{p}. These determine
R = omega_{a} / omega_{p} = 3.707~201(19) times 10^{-3}. With mu_{mu} /
mu_{p} = 3.183~345~39(10) this gives a_{mu^+} = 11~659~191(59) times 10^{-10}
(pm 5 ppm), in good agreement with the previous CERN and BNL measurements for
mu^+ and mu^-, and with the standard model prediction.Comment: 4 pages, 4 figures. accepted for publication in Phys. Rev. D62 Rapid
Communication
The Muon Anomalous Magnetic Moment and the Standard Model
The muon anomalous magnetic moment measurement, when compared with theory,
can be used to test many extensions to the standard model. The most recent
measurement made by the Brookhaven E821 Collaboration reduces the uncertainty
on the world average of a_mu to 0.7 ppm, comparable in precision to theory.
This paper describes the experiment and the current theoretical efforts to
establish a correct standard model reference value for the muon anomaly.Comment: Plenary Talk; PANIC'02 XVI Particles and Nuclear International
Conference, Osaka, Japan; Sept. 30 - Oct. 4, 2002; Report describes the
published 0.7 ppm result and updates the theory statu
Search for Lorentz and CPT Violation Effects in Muon Spin Precession
The spin precession frequency of muons stored in the storage ring has
been analyzed for evidence of Lorentz and CPT violation. Two Lorentz and CPT
violation signatures were searched for: a nonzero
(=); and a sidereal variation of
. No significant effect is found, and the following
limits on the standard-model extension parameters are obtained: GeV; GeV; and the 95% confidence level limits
GeV and
GeV.Comment: 5 pages, 3 figures, submitted to Physical Review Letters, Modified to
answer the referees suggestion
News from the Muon (g-2) Experiment at BNL
The magnetic moment anomaly a_mu = (g_mu - 2) / 2 of the positive muon has
been measured at the Brookhaven Alternating Gradient Synchrotron with an
uncertainty of 0.7 ppm. The new result, based on data taken in 2000, agrees
well with previous measurements. Standard Model evaluations currently differ
from the experimental result by 1.6 to 3.0 standard deviations.Comment: Talk presented at RADCOR - Loops and Legs 2002, Kloster Banz,
Germany, September 8-13 2002, to be published in Nuclear Physics B (Proc.
Suppl.); 5 pages, 3 figure
Final Report of the Muon E821 Anomalous Magnetic Moment Measurement at BNL
We present the final report from a series of precision measurements of the
muon anomalous magnetic moment, a_mu = (g-2)/2. The details of the experimental
method, apparatus, data taking, and analysis are summarized. Data obtained at
Brookhaven National Laboratory, using nearly equal samples of positive and
negative muons, were used to deduce a_mu(Expt) = 11 659 208.0(5.4)(3.3) x
10^-10, where the statistical and systematic uncertainties are given,
respectively. The combined uncertainty of 0.54 ppm represents a 14-fold
improvement compared to previous measurements at CERN. The standard model value
for a_mu includes contributions from virtual QED, weak, and hadronic processes.
While the QED processes account for most of the anomaly, the largest
theoretical uncertainty, ~0.55 ppm, is associated with first-order hadronic
vacuum polarization. Present standard model evaluations, based on e+e- hadronic
cross sections, lie 2.2 - 2.7 standard deviations below the experimental
result.Comment: Summary paper of E821 Collaboration measurements of the muon
anomalous magnetic moment, each reported earlier in Letters or Brief Reports;
96 pages, 41 figures, 16 tables. Revised version submitted to PR
Search for Lorentz and CPT Violation Effects in Muon Spin Precession
The spin precession frequency of muons stored in the storage ring has
been analyzed for evidence of Lorentz and CPT violation. Two Lorentz and CPT
violation signatures were searched for: a nonzero
(=); and a sidereal variation of
. No significant effect is found, and the following
limits on the standard-model extension parameters are obtained: GeV; GeV; and the 95% confidence level limits
GeV and
GeV.Comment: 5 pages, 3 figures, submitted to Physical Review Letters, Modified to
answer the referees suggestion
An Improved Limit on the Muon Electric Dipole Moment
Three independent searches for an electric dipole moment (EDM) of the
positive and negative muons have been performed, using spin precession data
from the muon g-2 storage ring at Brookhaven National Laboratory. Details on
the experimental apparatus and the three analyses are presented. Since the
individual results on the positive and negative muon, as well as the combined
result, d=-0.1(0.9)E-19 e-cm, are all consistent with zero, we set a new muon
EDM limit, |d| < 1.9E-19 e-cm (95% C.L.). This represents a factor of 5
improvement over the previous best limit on the muon EDM.Comment: 19 pages, 15 figures, 7 table
Development and evaluation of a new fully automatic motion detection and correction technique in cardiac SPECT imaging
In cardiac SPECT perfusion imaging, motion correction of the data is critical to the minimization of motion introduced artifacts in the reconstructed images. Software-based (data-driven) motion correction techniques are the most convenient and economical approaches to fulfill this purpose. However, the accuracy is significantly affected by how the data complexities, such as activity overlap, non-uniform tissue attenuation, and noise are handled.
We developed STASYS, a new, fully automatic technique, for motion detection and correction in cardiac SPECT. We evaluated the performance of STASYS by comparing its effectiveness of motion correcting patient studies with the current industry standard software (Cedars-Sinai MoCo) through blind readings by two readers independently.
For 204 patient studies from multiple clinical sites, the first reader identified (1) 69 studies with medium to large axial motion, of which STASYS perfectly or significantly corrected 86.9% and MoCo 72.5%; and (2) 20 studies with medium to large lateral motion, of which STASYS perfectly or significantly corrected 80.0% and MoCo 60.0%. The second reader identified (1) 84 studies with medium to large axial motion, of which STASYS perfectly or significantly corrected 82.2% and MoCo 76.2%; and (2) 34 studies with medium to large lateral motion, of which STASYS perfectly or significantly corrected 58.9% and MoCo 50.0%.
We developed a fully automatic software-based motion correction technique, STASYS, for cardiac SPECT. Clinical studies showed that STASYS was effective and corrected a larger percent of cardiac SPECT studies than the current industrial standard software
- …